| 1. |
If you have Visual
Chart 4. You must download the file of the system
(with .FLW or .VBA extension) into the folder C:\Program Files\vChart4\Documents\VBA\systems,
if you have installed Visual Chart in the default folder. |
| 2. |
If you
have Visual Chart 3. You
must download the file of the system (with .FLW or .VBA extension)
into the folder C:\Program Files\vChart3\Documents\VBA\systems,
if you have installed Visual Chart in the default folder. |
| 3. |
Once you have loaded Visual
Chart, you have to go to the Systems menu, and click
Modify System. In the window that will open you have
to select the downloaded file and open it. A new window will open,
which will be different depending on the file having FLW or VBA
extension. |
| 4. |
If the downloaded file has
FLW extension (the system has been created with the Visual Design
Platform), you need to compile it clicking the "Create System\Oscillator\Study" . |
| 5. |
On the other hand, if the
file has VBA extension, you have to compile the system opening the
Debug menu, and then clicking Publish
. |
| 1. |
If you have Visual
Chart 4. You must download the file of the system
(with .FLW or .VBA extension) into the folder C:\Program Files\vChart4\Documents\VBA\Indicators,
if you have installed Visual Chart in the default folder. |
| 2. |
If you
have Visual Chart 3. You
must download the file of the system (with .FLW or .VBA extension)
into the folder C:\Program Files\vChart3\Documents\VBA\Indicators,
if you have installed Visual Chart in the default folder. |
| 3. |
Once you have loaded Visual
Chart, you have to go to the Systems menu, and click
Modify Indicator. In the window that will open you
have to select the downloaded file and open it. A new window will
open, which will be different depending on the file having FLW or
VBA extension. |
| 4. |
If the downloaded file has
FLW extension (the system has been created with the Visual Design
Platform), you need to compile it clicking the "Create System\Oscillator\Study" . |
| 5. |
On the other hand, if the
file has VBA extension, you have to compile the system opening the
Debug menu, and then clicking Publish
. |
| 1. |
If you have Visual
Chart 4. You must download the file of the system
(with .FLW or .VBA extension) into the folder C:\Program Files\vChart4\Documents\VBA\Studies,
if you have installed Visual Chart in the default folder. |
| 2. |
If you
have Visual Chart 3. You
must download the file of the system (with .FLW or .VBA extension)
into the folder C:\Program Files\vChart3\Documents\VBA\Studies,
if you have installed Visual Chart in the default folder. |
| 3. |
Once you have loaded Visual
Chart, you have to go to the Systems menu, and click
Modify Study. In the window that will open you have
to select the downloaded file and open it. A new window will open,
which will be different depending on the file having FLW or VBA
extension. |
| 4. |
If the downloaded file has
FLW extension (the system has been created with the Visual Design
Platform), you need to compile it clicking the "Create System\Oscillator\Study" . |
| 5. |
On the other hand, if the
file has VBA extension, you have to compile the system opening the
Debug menu, and then clicking Publish
. |
|